LPS150 Series WebSheet
| Print
Resources & Downloads
- Total Max Power: 175 W
- Total Max Current: 22 A
- Input Voltage: 85 V to 264 V
- Output Voltage: 4.5 V to 48 V
- Outputs: Single
- Size (L x W x H): 4.250" x 8.500" x 1.500"
- Warranty: 2 years
- Operating Temperature: 0 to +70 C
Electrical Specifications
Input
- Input range: 85-132 VAC or 170-264 VAC automatically selected. 220-300 VDC
- Frequency: 47-63 Hz
- EMI filter: FCC Class B conducted CISPR 22 Class B conducted EN55022 Class B conducted VDE 0878 PT3 Class B conducted
- Inrush current: 38 A max, cold start @ 25°C
- Safety ground leakage current: <0.5 mA @ 50/60 Hz, 264 VAC input
- Efficiency: 75% typical at full load
Output
- Overvoltage protection: 5 V output: 5.7 to 6.7 VDC. Other outputs 10% to 25% above nominal output
- Overload protection: Short circuit protection. Case overload protected @ 110% to 145% above peak rating
- Hold-up time: 20 ms @ 110 W load, 115/230 VAC
- Adjustment range: ±5% minimum
- Maximum power: 110 W convection (75 W with cover) 150 W with 30 CFM forced air (130 W with cover)
Logic Control
- Power Failure: TTL Logic signal goes high 50-150 msec after 5 V output. It goes low at least 3 ms before loss of regulation.
- Remote inhibit: Requires an external TTL high signal to inhibit outputs.
- Remote sense: Compensates for 0.5 V lead drop minimum, will operate without remote sense connected. Reverse connection protected.
- Remote sense
- Single wire current sharing
- 135 khz switching frequency
- Auto ranging input
- Power fail
- Built-in EMI filter
- Low output ripple
- Adjustable output
- Overload protection
- Optional cover (-C suffix).
- Remote inhibit
- Overvoltage protection









Datasheet