LPT60-M Medical Series WebSheet
Product Summary
The LPT60-M AC-DC power supply series offers a power output of 80 watts at max current of 8.5 Amps with triple outputs from -15 to 24 V. The series accepts a universal input voltage of 85 to 264 Vac with a form factor of 3" x 5". The LPT60-M comes with medical safety approvals and is designed for low-profile applications.
Resources & Downloads
- Total Max Power: 80 W
- Total Max Current: 8 A
- Input Voltage: 852 V to 264 V
- Output Voltage: -15 V to 19.5 V
- Outputs: Triple
- Size (L x W x H): 5.000" x 3.000" x 1.650"
- Warranty: 2 years
- Operating Temperature: -20 to +70°C
Electrical Specifications
Input
- Efficiency: 70% typical at full load
- Inrush current: < 18 A peak @ 115 Vac; < 36 A peak @ 230 Vac
- Frequency: 47 - 440 Hz
- Input current: 1.5 A max. (RMS) @ 115 Vac
- Safety ground leakage current: < 0.5 mA @ 50/60 Hz, 264 Vac input
- EMI filter: FCC Class A conducted CISPR 22 Class A conducted
- Input range: 85 - 264 Vac, 120-300 Vdc
Output
- Adjustment range: -5, +10% minimum
- Remote sense: Compensates for 0.5 V lead drop min.
- Cross regulation: ± 2% on output 1; ± 5% on outputs 2,3
- Overload protection above peak rating: Short circuit protection on all outputs
- Hold-up time: 20 ms @ 60 W load, 115 Vac nominal line
- Maximum power: 60 W for convection; 80 W with 30 CFM
- Medical safety approvals
- Universal input
- 3" x 5" footprint
- Remote sense on main output
- Built-in EMI filter
- Adjustable main output
- LPX60 enclosure kit available
- Low output ripple
- Overload protection
- 110 KHz switching frequency
- Overvoltage protection