MTC600 Series WebSheet
Product Summary
The MTC600 series of power modules is designed for use in MicroTCA systems and can support shelves, cubes and other system implementations. The models are fully compliant with PICMG MicroTCA systems comprising of up to: 12x AdvancedMC's, 2x MicroTCA Carrier Hubs (MCH) and 2x Cooling Units. With both AC and DC inputs, the versatile product series provides the power necessary for MCH and CU system elements.
Resources & Downloads
- Total Max Power: 600 W
- Total Max Current: 50 A
- Input Voltage: 90 V to 264 V
- Output Voltage: 3.16 V to 12.95 V
- Outputs: Single
- Size (L x W x H): 7.370" x 2.340" x 2.890"
- Warranty: 2 years
- Operating Temperature: -5°C to +45°C
Electrical Specifications
Input
- Inrush Current: <=45A (AC INP) <=80A (DC INP)
- Reverse Input Protection: Included (DC Input)
- Hold-up Time: 16.7 ms min (AC INP) 5 ms min (DC INP)
- Input Current: 6.6 A max (AC INP) 18.2 A max (DC INP)
- Power Factor (AC Input): 0.99 Typical
- Input Frequency (AC Input): 47 - 63 Hz
- Input Range (AC Input): 90 - 264 VAC
- Input Range (DC Input): -39.5 to -72 VDC
Output
- Total Regulation: 12.25 V - 12.95 V; 11.60 V - 12.00 V (Pri/Rednt)
- Output Rise Time (Per Channel): 25 ms Max
- Set Point: 12.6 V (Primary PM); 11.8 V (Redundant PM)
- Output noise (PARD): 100 mV max
- Rated Load (each output): 80 W/7.6 A max
Logic Control
- Turn-on time: 4 Seconds max
- Interface Protocol: PM-EMMC Aggregates IPMB-A and -B IPMI v1.5
- 600 W total output power
- 16 Channels of 12 V @ 7.5 A max, 3.3 V @ 150 mA max
- Supports:12x AMC's, 2x MCH's, and 2x CU's
- Supports N+1 Redundancy, N<=3
- Supports Redundant IPMI (IPMB-0) communication with the MCH/Carrier-Manager
- Under the command of the carrier manager, enable and provide power to AMC's, CU's and additional MCH's
- Monitor and Report power system status and conditions of operation
- Manage and isolate faults affecting the power system