HPS35 Series WebSheet
- Total Max Power: 350 W
- Total Max Current: 29 A
- Input Voltage: 90 V to 264 V
- Output Voltage: 11.4 V to 52.8 V
- Outputs: 0, Single
- Size (L x W x H): 11.050" x 3.070" x 1.570"
- Warranty: 2 years
- Operating Temperature: 0 to +50 C
Download Datasheet
Special features
-
Hot Plug
-
Remote inhibit
-
Overcurrent protection (OCP)
-
No minimum load
-
5VSB@2A
-
DC OK signal and indicator LED
-
CISPR22, EN55022 Class-B conducted/radiated EMI
-
Active Power Factor Correction
-
AC OK signal and indicator LED
-
N+1 Redundant
-
Remote Sense on main output
-
Overtemperature protection (OTP)
-
EN61000 immunity standards
-
EN61000-3-2 compliant
-
Optional I2C board (pending)
-
Overvoltage protection (OVP)
Electrical specs
Input
- Input voltage: 90-264 VAC typical
- Inrush current: 40 A peak typical @ 25°C
- Power factor: 0.98 typical @ 115 VAC, full load
- Leakage current standard: <0.5 mA max @ 230 VAC @ 60Hz (per module)
- Holdup time: 20 ms minimum (independent of input VAC)
- Harmonic distortion: Meets EN61000-3-2
- Frequency: 47-440 Hz
- Efficiency: 80% typ @ full load, 230 VAC
- Turn-on time: AC - ON 2 sec.
- EMI filter standard: CISPR 22 EN55022 Level “B"
- Radiated EMI: CISPR 22 EN55022 Level “B"
- AC OK: 5 ms early warning minimum before outputs lose regulation
- Isolation: Meets EN60950
Output
- Adjustability: ±5% of nominal output voltage
- Overall reg: ±2%
- Dynamic response: 4% with 50% load step
- Recovery time: To within 1% in <300 µsec
- Overcurrent protection: 115%-130% of rated output current
- Overvoltage protection: 120 - 140% . AC Reset.
- Thermal protection: Main and Aux disabled when internal temp exceeds safe operating range.
- Single wire parallel: Current share to within 10% of total rated current on main output
- Minimum load: Not required
- Global Inhibit: Logic '0'
- Ripple: 1% of Vout Pk - Pk (20 MHz bandwidth)
- Short circuit protection: Protected for continuous short circuit. Auto recovery.
- Reverse voltage protection: 100% of rated output current
- Remote sense: Up to 0.5 V total drop
- Standby voltage: 5 VDC @2A max. present whenever AC input is applied
HPS35 models