LPS170 Series WebSheet
- Total Max Power: 175 W
- Total Max Current: 22 A
- Input Voltage: 85 V to 264 V
- Output Voltage: 2.5 V to 54 V
- Outputs: Single
- Size (L x W x H): 4.250" x 8.500" x 1.500"
- Warranty: 2 years
- Operating Temperature: 0 to +70 C
Download Datasheet
Special features
- Built-in EMI filter
-
5 V standby output
-
DC power good
-
Optional cover (-C suffix)
-
Thermal overload protection
-
Overvoltage protection
-
Low output ripple
-
Active power factor correction
-
IEC EN61000-3-2 compliance
-
Wide Range Adjustable output
-
Remote sense on main output
-
12 V Aux output
-
Overload protection
-
Power fail and remote inhibit
-
Single wire current sharing
Electrical specs
Input
- Frequency: 47-63 Hz
- Efficiency: 75% typical at full load
- Input range: 85-264 VAC, 120-300 VDC
- EMI filter: Meets FCC Class B conducted CISPR 22 Class B
- Safety ground leakage current: 1.0 mA @ 50/60 Hz, 264 VAC input
- Power factor: 0.99 typical
- Inrush current: 38 A max, cold start @ 25°C
Output
- Hold-up time: 20 ms @175 W load at nominal line
- Adjustment range: 2:1 wide ratio minimum
- Maximum power: 110 W convection, 75 W w/cover, 175 W w/ 30 CFM
- Overvoltage protection: 10% to 40% above nominal output
- Overload protection: Short circuit protection on all outputs.
- Standby output: 5 V @ 2 A regulated ±5%
- Aux output: 12 V @ 1 A -5 %, +10%
Logic Control
- Remote sense: Compensates for 0.5 V lead drop min. Will operate
- DC Ok: TTL logic signal goes high after main output is in
- Power failure: TTL logic signal goes high 100 - 500 msec after V1
- Remote inhibit: Requires contact closure to inhibit outputs
LPS170 models